Home      About this journal      Authors      Referees      Editors      Readers      Archive      Contact us
Determination of ginsenoside Rg1 in Shunaoxin capsules by HPLC
Hits 1561  Download times 1845  Received:October 20, 2010  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1673-9043.2011.01.17
Key Words   ginsenoside Rg1;HPLC;Shunaoxin capsules;content determination
Author NameAffiliation
JIA Guiyan Shenzhen Taitai Healthcare Food Co. Ltd, Shenzhen 518057, China
 
MA Li Tianjin Institute of Pharmaceutical Research, Tianjin 300193, China 
HAN Feng Tianjin Institute of Pharmaceutical Research, Tianjin 300193, China 
陈刚 
1. Shenzhen Taitai Healthcare Food Co. Ltd, Shenzhen 518057, China

2. Tianjin Institute of Pharmaceutical Research, Tianjin 300193, China
 
Abstract
    [Objective] To establish a method for the content determination of ginsenoside Rg1 in Shunaoxin capsules.[Method] A simple HPLC method for determination of ginsenoside Rg1 was established.The determination was carried out taking column as the mobile phase of acetonirile-water (85:15) and detection wave-length was 203nm.[Result] The ginsenoside Rg1 input sample size showed a good linear relationship at the range of 0.5428~2.715μg and the correlation coefficient was 0.999 8.The average recovery of the added sample was 97.24%.RSD was 1.43%.[Conclusion] The method is simple,accurate,reproducible and can be used for content determination of ginsenoside Rg1 in jiangzhi capsules.

You are the 1622061 visitor.

Copyright @ 2007
Address:   Postcode:
Tel:  Fax:  E-mail: