Simultaneous determination of luteolin-7-O-glu-coside and chlorogenic acid in Flos Lonicerae Japonicae by HPLC |
Hits 1972 Download times 2189 Received:February 11, 2011 |
View Full Text View/Add Comment Download reader |
DOI
10.11656/j.issn.1673-9043.2011.02.14 |
Key Words
HPLC;Flos Lonicerae Japonicae;chlorogenic acid;luteolin-7-O-glucoside;quantitative determination |
Author Name | Affiliation | ZHANG Yuan-yuan | Tianjin University of TCM, Tianjin 300193, China | LI Jin | The First Hospital Affiliated to Tianjin University of TCM, Tianjin 300193, China | CHEN Tao | The First Hospital Affiliated to Tianjin University of TCM, Tianjin 300193, China | 李凤丽 | The First Hospital Affiliated to Tianjin University of TCM, Tianjin 300193, China |
|
Abstract
|
[Objective] To establish a HPLC method for quantitative determination of luteolin-7-O-glu-coside and chlorogenic acid in Flos Lonicerae Japonicae using gradient elution method. [Methods] Determining column:Xterra@ RP 185;Detector:Waters 2 998 diode array detector (DAD);Workstation:Waters Empower;The mobile phase:0.5% acetic acid-acetonitrile;Linear gradient elution:0~15min (90:10-80:20),15~30 min (80:20-75:25), 30~40 min (75:25-65:35), 40~45 min (65:35-90:10);The flow rate was 1 mL/min, and the detection wavelength was set at 350 nm. [Results] In this chromatographic conditions, the two components were completely separated. [Conclusion] The method is simple, accurate, fast and easy, which can detect two components of Flos Lonicerae Japonicae simultaneously. |
|
|
|
|
|