Home      About this journal      Authors      Referees      Editors      Readers      Archive      Contact us
SPE-LC-MS/MS method for determination of hypoxanthine concentration in Shuxuetong injection
Hits 1511  Download times 1032  Received:May 20, 2019  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1673-9043.2019.05.16
Key Words   LC-MS/MS;solid phase extraction;Shuxuetong injection;hypoxanthine;quantitative determination
Author NameAffiliationE-mail
WANG Xianrui Tianjin University of Traditional Chinese Medicine, Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin 300193, China  
ZHAO Xizi Tianjin University of Traditional Chinese Medicine, Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin 300193, China  
WANG Xiaoming Tianjin University of Traditional Chinese Medicine, Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin 300193, China  
GUO Yaqing Tianjin University of Traditional Chinese Medicine, Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin 300193, China  
PAN Guixiang Second Affiliated Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin 300250, China guixiangp@163.com 
HUANG Yuhong Second Affiliated Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin 300250, China  
Abstract
    [Objective] Solid phase extraction with liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) was applied to determine the concentration of hypoxanthine in Shuxuetong injection.[Methods] After extracted with SPE column,Shuxuetong injection was detected by LC-MS/MS. This injection was separated on an Acquity BEH C18 column (100 mm×2.1 mm,1.7 μm),and methanol-water (containing 0.1% formic acid) was used as a mobile phase for gradient elution at a flow rate of 0.3 mL/min. Mass spectrometric detection was performed in negative ion and multiple reaction monitoring mode with an electrospray ionization (ESI) source. The ion pairs used for quantitative analysis were m/z 134.9→92.0 for hypoxanthine and m/z 151.0→92.1 for 6-mercaptopurine (internal standard,IS).[Results] Hypoxanthine had a good linear relationship with the peak area ratio of the analyte and the IS in the range of 0.1~0.5 μg/mL (r=0.999 8). The average recovery rate was 98.7%,and the RSD was 0.31%.[Conclusion] This method described here is a simple,accurate and sensitive method that can be used for the determination of hypoxanthine concentrationin Shuxuetong injection.

You are the 1620447 visitor.

Copyright @ 2007
Address:   Postcode:
Tel:  Fax:  E-mail:
Beijing E-Tiller Co., Ltd.