Home      About this journal      Authors      Referees      Editors      Readers      Archive      Contact us
Simultaneous determination of eight compounds in Yinxu Weitong Granules by HPLC-QAMS
Hits 657  Download times 378  Received:December 20, 2021  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1673-9043.2022.03.18
Key Words   Yinxu Weitong Granules;HPLC-QAMS;multi-index component;RCF
Author NameAffiliationE-mail
CHEN Xiaocun Dazhou Hospital of Integrated Traditional Chinese and Western Medicine, Dazhou 635000, China  
WEI Tanjun Dazhou Hospital of Integrated Traditional Chinese and Western Medicine, Dazhou 635000, China hotq1323@163.com 
CHEN Fei Dazhou Hospital of Integrated Traditional Chinese and Western Medicine, Dazhou 635000, China  
XIAO Cheng Dazhou Hospital of Integrated Traditional Chinese and Western Medicine, Dazhou 635000, China  
CHEN Yong Chengdu Diao Group Tianfu Pharmaceutical Co. Ltd., Dazhou 635027, China  
Abstract
    [Objective] To establish an HPLC-QAMS method for simultaneous determination of oxypaeoniflorin, albiflorin, paeoniflorin, benzoylpaeoniflorin, methylophiopogonanone A, methylophiopogonanone B, falcarindiol and panaxynol in Yinxu Weitong Granules, and to establish the multi-index components quality evaluation model for Yinxu Weitong Granules.[Methods] The Agilent HC C18 column was used, and the mobile phase consisted of acetonitrile-0.1% phosphoric acids solution with gradient elution, and the flow rate was 1.0 mL/min;The column temperature was 30℃;The detection wavelength were 230, 296 and 254 nm;The injection volume was 10 μL. With paeoniflorin as the internal reference, the relative correction factor(RCF) with other seven components was established, and the content of each component was calculated. The external standard method(ESM) was used to determine the contents of 8 components in Yinxu Weitong Granules to verify the accuracy of the calculation results of the QAMS.[Results] The 8 components have a good linear relationship within their respective ranges(r ≥ 0.999 1), whose average recoveries(RSD) were 98.90%(1.01%), 100.02%(0.94%), 99.52%(0.76%), 97.88%(1.35%), 99.14%(1.42%), 96.85%(0.65%), 97.83%(0.92%) and 98.65%(1.24%), respectively. There was no significant difference between HPLC-QAMS and ESM.[Conclusion] The established HPLC-QAMS method is convenient and accurate, which can be used for simultaneous determination of eight compounds in Yinxu Weitong Granules.

You are the 1631972 visitor.

Copyright @ 2007
Address:   Postcode:
Tel:  Fax:  E-mail:
Beijing E-Tiller Co., Ltd.