Home      About this journal      Authors      Editors      Readers      Archive      Contact us
Study on dissolution test method of Silybin Solid Dispersion Capsules
Hits 1951  Download times 1478  Received:October 20, 2003  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1672-1519.2004.01.33
Key Words   silybin;solid;dispersion;dissolution
Author NameAffiliation
REN Xiao-wen Tianjin Institute of Medicine, Tianjin 300193, China 
XU Wei-ren Tianjin Institute of Medicine, Tianjin 300193, China 
LIAN Xiao-yan Tianjin Institute of Medicine, Tianjin 300193, China 
马晋 Tianjin Institute of Medicine, Tianjin 300193, China 
李洪起 Tianjin Institute of Medicine, Tianjin 300193, China 
Abstract
    [Objective] To establish a method in determining the dissolution of silybin solid dispersion capsules. [Methods] According to the description in Chp.2000.VolⅡ.Appendix XC, the dissolution of silybin solid dispersion capsules was determined by UV-VIS spectrophotometer. [Results] The selected media for dissolution test is phosphate buffer solution with 0.5% Brij35 (pH7.8~8.0).The dissolution of capsules has good reproducibility. [Conclusion] The method is considered to be a accurate and reliable dissolution determination for silybin capsules.

You are the 2303974 visitor.

Copyright @ 2007
Address: 10 Boyanghu Road, West District of Tuanbo New City, Jinghai District, Tianjin 301617, China  Postcode:
Tel:  Fax:  E-mail:
Beijing E-Tiller Co., Ltd.