| Experimental study on effect of electro-heated stone needle on local skin blood perfusion of dorsum hand |
| Hits 2365 Download times 2293 Received:April 15, 2009 |
| View Full Text View/Add Comment Download reader |
| DOI
10.11656/j.issn.1672-1519.2009.05.16 |
| Key Words
skin blood perfusion;electro-heated stone needle therapy;laser doppler perfusion imaging |
| Author Name | Affiliation | | WANG Guang-Jun | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | ZHANG Yu-qin | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | WANG Rui-hong | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | 丁玉龙 | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | 田宇瑛 | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | 黄涛 | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China | | 张维波 | Medical engineering Lab, Institute of Acupuncture and Moxibustion, China Academy of Chinese Medical Science, Beijing 100070, China |
|
| Abstract
|
| [Objective] To observe the effect of electro-heated stone needle on the blood perfusion of dorsum of hand and to investigate the mechanism of the therapy. [Methods] Stimulation the third and 4th interosseous space of metacarpus of right hand by the 45℃ stone needle was performed and then the change of blood perfusion in the area of dorsum of hand and periumbilicus was observed with laser Doppler blood perfusion imaging system. [Results] After stimulation,the blood perfusion of right hand increased markedly (compared with pre-stimulation,P<0.01),and the attenuation of the increased blood perfusion was not noted within 30 minutes after stimulation. On the other hand,there was not significant change of the blood perfusion in periumbilicus area within 30 minutes after stimulation. [Conclusion] Electro-heated stone needle therapy can increase skin local blood perfusion of dorsum of hand without any effect on the periumbilicus area. |
|
|
|
|
|
|
|