Home      About this journal      Authors      Editors      Readers      Archive      Contact us
Determination of Danshensu sodium in new shengmaisan tablet by HPLC
Hits 1388  Download times 1431  Received:December 20, 2011  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1672-1519.2012.02.24
Key Words   HPLC;Sodium of Danshensu;new shengmaisan tablet;quantitative determination
Author NameAffiliation
HU Xiao-qin Tianjin University of TCM, Tianjin 300193, China 
LI Jin The First Affiliated Hospital of Tianjin University of TCM, Tianjin 300193, China 
CHEN Tao The First Affiliated Hospital of Tianjin University of TCM, Tianjin 300193, China 
LI Feng-li The First Affiliated Hospital of Tianjin University of TCM, Tianjin 300193, China 
Abstract
    [Objective] To establish a method for determining sodium of Danshensu in new shengmaisan tablet. [Methods] Chromatography column: Xterra @ RP185 was used; the mobile phase consisted of methanol-1% acetic acid (2:98); the flow rate was 1.0 mL/min; the detection wavelength was 280 nm. [Results] The calibration curve showed a good linear correlation within the concentration range of 0.15~2.4 μg/mL (r=0.999 9) with satisfied precision, repetition, stability and recovery. [Conclusion] The method is convenient, accurate and specific. It could be used for the quality control of new shengmaisan tablet.

You are the 2312702 visitor.

Copyright @ 2007
Address: 10 Boyanghu Road, West District of Tuanbo New City, Jinghai District, Tianjin 301617, China  Postcode:
Tel:  Fax:  E-mail:
Beijing E-Tiller Co., Ltd.