Home      About this journal      Authors      Editors      Readers      Archive      Contact us
Determination of sodium and potassium in Danhong injection by atomic absorption spectrometry
Hits 1495  Download times 1634  Received:November 24, 2015  
View Full Text  View/Add Comment  Download reader
DOI   10.11656/j.issn.1672-1519.2016.01.11
Key Words   Danhong injection;sodium ion;potassium ion;atomic absorption spectrometry
Author NameAffiliationE-mail
WANG Yan Tianjin State Key Laboratory of Modern Chinese Medicine, Province and Ministry Co-established State Key Laboratory Cultivation Base, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China
Research and Development Center of Traditional Medicine, Tianjin International Joint Academy of Biotechnology and Medicine, Tianjin 300457, China 
 
JIAO Yu-jiao Tianjin State Key Laboratory of Modern Chinese Medicine, Province and Ministry Co-established State Key Laboratory Cultivation Base, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China
Research and Development Center of Traditional Medicine, Tianjin International Joint Academy of Biotechnology and Medicine, Tianjin 300457, China 
 
ZHU Yan Tianjin State Key Laboratory of Modern Chinese Medicine, Province and Ministry Co-established State Key Laboratory Cultivation Base, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China
Research and Development Center of Traditional Medicine, Tianjin International Joint Academy of Biotechnology and Medicine, Tianjin 300457, China 
 
WANG Yue-fei Tianjin State Key Laboratory of Modern Chinese Medicine, Province and Ministry Co-established State Key Laboratory Cultivation Base, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China
Research and Development Center of Traditional Medicine, Tianjin International Joint Academy of Biotechnology and Medicine, Tianjin 300457, China 
 
YANG Jing Tianjin State Key Laboratory of Modern Chinese Medicine, Province and Ministry Co-established State Key Laboratory Cultivation Base, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, China
Research and Development Center of Traditional Medicine, Tianjin International Joint Academy of Biotechnology and Medicine, Tianjin 300457, China 
yangjingfei_2006@163.com 
Abstract
    [Objective] To establish and validate the determination method of the content of sodium ion and potassium ion in Danhong injection by atomic absorption spectrometry (AAS). [Methods] Microwave digestion system was applied to deteriorate samples, and the content of sodium ion and potassium ion was determined by AAS. [Results] The calibration curve of sodium was liner (r=0.999 8) in the range from 0.1 to 0.6 mg/L. The average recovery was 101.1% with RSD 1.8%. The limit of detection was 5.3 μg/L. The calibration curve of potassium was liner (r=0.999 8) in the range from 0.1 to 0.8 mg/L. The average recovery was 99.8% with RSD 2.3%. The limit of detection was 7.7 μg/L. The determination results of 10 batches Danhong injection sample showed that the content of sodium ion was 562.3 to 734.7 mg/L and potassium ion was 206.9 to 314.4 mg/L. [Conclusion] The method is simple and accurate and can be used for determination of the contents of sodium ion and potassium ion in Danhong injection. The accurate quantitative determination method can be promoted to quality control of Danhong injection.

You are the 2302964 visitor.

Copyright @ 2007
Address: 10 Boyanghu Road, West District of Tuanbo New City, Jinghai District, Tianjin 301617, China  Postcode:
Tel:  Fax:  E-mail:
Beijing E-Tiller Co., Ltd.